電(dian)伴(ban)(ban)(ban)熱(re)廠家(jia)建議根據管道管徑和長(chang)度選用電(dian)伴(ban)(ban)(ban)熱(re)帶(dai)(dai)(dai)(dai)(dai)的(de)(de)型號及長(chang)度。安(an)裝電(dian)熱(re)帶(dai)(dai)(dai)(dai)(dai)時不(bu)應(ying)打(da)硬折(zhe)或(huo)長(chang)距離在地面(mian)拖(tuo)拽。碰到銳利(li)的(de)(de)邊棱(leng)要先(xian)(xian)墊上(shang)鋁(lv)箔膠帶(dai)(dai)(dai)(dai)(dai)或(huo)將(jiang)其(qi)銳利(li)處打(da)磨光滑,以防將(jiang)電(dian)熱(re)帶(dai)(dai)(dai)(dai)(dai)外層邊緣劃破。電(dian)伴(ban)(ban)(ban)熱(re)帶(dai)(dai)(dai)(dai)(dai)的(de)(de)最小彎曲半徑應(ying)不(bu)小于(yu)沃安(an)電(dian)氣廠家(jia)樣本(ben)中的(de)(de)規定(ding)值。電(dian)伴(ban)(ban)(ban)熱(re)帶(dai)(dai)(dai)(dai)(dai)的(de)(de)最小彎曲半徑應(ying)不(bu)小于(yu)廠家(jia)樣本(ben)中的(de)(de)規定(ding)值。電(dian)伴(ban)(ban)(ban)熱(re)帶(dai)(dai)(dai)(dai)(dai)應(ying)緊貼(tie)設備、管道表(biao)面(mian),以利(li)熱(re)傳導,安(an)裝時,先(xian)(xian)清除伴(ban)(ban)(ban)熱(re)電(dian)纜途(tu)徑處的(de)(de)油污、水分或(huo)其(qi)他臟(zang)物,在每(mei)隔一定(ding)距離應(ying)用專用膠帶(dai)(dai)(dai)(dai)(dai)將(jiang)電(dian)伴(ban)(ban)(ban)熱(re)帶(dai)(dai)(dai)(dai)(dai)固定(ding),同時確保管道表(biao)面(mian)與電(dian)伴(ban)(ban)(ban)熱(re)帶(dai)(dai)(dai)(dai)(dai)保持緊密結合。
1、電熱帶尾端處按45度切成鈍角,尾端必須(xu)用終端接(jie)線盒做(zuo)好防水絕緣處理(li)。接(jie)線時兩個(ge)尾端的(de)銅絲不要相(xiang)連,這(zhe)樣尾端銅絲相(xiang)連造(zao)成的(de)短路的(de)。
2、電(dian)熱(re)(re)帶(dai)(dai)(dai)電(dian)源接(jie)線(xian)(xian)端剪成不(bu)等式,電(dian)熱(re)(re)帶(dai)(dai)(dai)與電(dian)源線(xian)(xian)連接(jie)處(chu)應牢固(gu),兩(liang)根接(jie)線(xian)(xian)端應用(yong)銅套(tao)管分別固(gu)定后接(jie)入終端接(jie)線(xian)(xian)盒(he)做防水絕緣處(chu)理(li),再(zai)用(yong)終端接(jie)線(xian)(xian)盒(he)從(cong)電(dian)熱(re)(re)帶(dai)(dai)(dai)的外絕緣處(chu)到兩(liang)芯電(dian)源線(xian)(xian)之間做二(er)次絕緣防水處(chu)理(li),以防電(dian)熱(re)(re)帶(dai)(dai)(dai)的發(fa)熱(re)(re)體滲(shen)水,導(dao)致電(dian)熱(re)(re)帶(dai)(dai)(dai)著火。
3、電伴熱帶在農村市場或木制起脊等靠近易(yi)燃物處安裝(zhuang)時,其管路必(bi)須做(zuo)好防火(huo)(huo)層處理或走外墻遠離易(yi)燃物,防火(huo)(huo)層可(ke)用鐵管或阻燃管等不易(yi)燃燒的物品隔離,如發現沒有(you)做(zuo)好防火(huo)(huo)處理,應及時排除(chu)安全隱患。
4、由于電(dian)(dian)(dian)(dian)熱(re)帶(dai)在(zai)通電(dian)(dian)(dian)(dian)瞬間電(dian)(dian)(dian)(dian)流過大,所有在(zai)選用(yong)(yong)電(dian)(dian)(dian)(dian)源(yuan)線(xian)時(shi)要注意;電(dian)(dian)(dian)(dian)熱(re)帶(dai)的(de)(de)(de)(de)長(chang)度(du)(du)不超過5米(mi)(mi)(mi)時(shi),選用(yong)(yong)國(guo)(guo)標0.5mm2的(de)(de)(de)(de)電(dian)(dian)(dian)(dian)源(yuan)線(xian),電(dian)(dian)(dian)(dian)熱(re)帶(dai)長(chang)度(du)(du)在(zai)5米(mi)(mi)(mi)以(yi)上(shang)選用(yong)(yong)國(guo)(guo)標0.75mm2的(de)(de)(de)(de)電(dian)(dian)(dian)(dian)源(yuan)線(xian),電(dian)(dian)(dian)(dian)熱(re)帶(dai)長(chang)度(du)(du)在(zai)15米(mi)(mi)(mi)以(yi)上(shang)選用(yong)(yong)國(guo)(guo)標1.0mm2的(de)(de)(de)(de)電(dian)(dian)(dian)(dian)源(yuan)線(xian),電(dian)(dian)(dian)(dian)熱(re)帶(dai)纏(chan)繞在(zai)50米(mi)(mi)(mi)以(yi)上(shang)時(shi)選用(yong)(yong)國(guo)(guo)標1.5mm2的(de)(de)(de)(de)電(dian)(dian)(dian)(dian)源(yuan)線(xian),電(dian)(dian)(dian)(dian)熱(re)帶(dai)長(chang)度(du)(du)在(zai)10米(mi)(mi)(mi)以(yi)上(shang)應選用(yong)(yong)國(guo)(guo)標2.5mm2的(de)(de)(de)(de)電(dian)(dian)(dian)(dian)源(yuan)線(xian)。
5、安裝伴熱(re)帶必須使用海源(yuan)電熱(re)提供的終端接線盒進行(xing)規范安裝。
6、由于伴熱(re)帶(dai)不(bu)能承受(shou)過(guo)大的拉力(li),固定點半熱(re)帶(dai)在(zai)PEX上時不(bu)能用膠帶(dai),鋁箔等纏繞過(guo)緊(jin),應(ying)用扎帶(dai)固定,固定間(jian)距為(wei)50cm。
7、電(dian)伴熱帶的電(dian)源必須使用5-10A漏電(dian)保(bao)護(hu)插(cha)頭保(bao)護(hu)開關。安裝過程避(bi)免過度折曲,避(bi)免折疊。
8、每年電伴熱帶(dai)重新使用(yong)時候必(bi)須檢查(cha)尾(wei)端與連接線短老(lao)化(hua)及絕緣(yuan)情況(kuang)、發現(xian)問題找沃(wo)安(an)電氣及時更換(huan)。
電伴熱(re)廠(chang)家全年在全國各地施(shi)工工程(cheng),對電伴熱(re)在防爆區、工廠(chang)區、民用區等環境有豐(feng)富的(de)施(shi)工經驗,如果(guo)您正在遇到(dao)這方面(mian)的(de)問題(ti),請前來咨詢(xun)。
上一篇:地下停車所用坡道融雪防滑電伴熱
下一篇:MI電纜在電伴熱應用中的角色